KEVOS® MAKEOS · Quality

Measurement Error from Part and Gauge Temperature

How far off is my measurement because the part and gauge are not at 20 °C, and what is the true size?

Size error when a part and the gauge or machine scale measuring it are at temperatures other than the 20 °C reference: the apparent deviation from their different expansions, the size corrected to 20 °C, the share of the tolerance the error uses, and the temperature difference that would keep the error within a chosen share of tolerance.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Nominal sizemmNominal length being measured.
Part expansion coefficientµm/m·KExpansion coefficient of the part (23 aluminium, 11.5 steel).
Part temperature°CTemperature of the part when measured.
Gauge or scale expansion coefficientµm/m·KExpansion coefficient of the gauge, scale or CMM (11.5 steel, about 0 for glass-ceramic scales).
Gauge temperature°CTemperature of the gauge or scale.
Measured size (0 = nominal)mmThe reading taken (0 uses the nominal size).
Total tolerance bandmmTotal tolerance band of the dimension.
Share of tolerance allowed for temperature%Share of the tolerance you allow for temperature effects.

Method and formulas

  1. Both expand from their 20 °C sizes: apparent deviation = L [α_p (T_p − 20) − α_g (T_g − 20)].
  2. Size at 20 °C = measured − deviation.
  3. For part and gauge at the same temperature, the error per kelvin is L |α_p − α_g|; allowable offset = share × tolerance ÷ (L |α_p − α_g|).
  4. Example: a 500 mm aluminium part at 28 °C measured with steel at 22 °C reads 80.5 µm large.

Limitations

  • Uniform temperatures; parts straight from machining have gradients.
  • Coefficients vary with alloy; use measured values for tight work.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Correct measurements taken on the shop floor
  • Decide how long parts must soak before inspection
  • Explain disagreements between shop and inspection measurements

Who it is for

  • Quality engineers
  • Tooling engineers
  • Metrology technicians

What you get

  • Apparent deviation from temperature
  • Size corrected to 20 °C
  • Share of tolerance used and allowable temperature difference

Interpreting the result

  • Equal temperatures do not remove the error when part and gauge are different materials.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 375–378, 2660. Topic reference; no source tables or recommended settings are reproduced.