KEVOS® MAKEOS · Materials
Differential Thermal Fit
How does clearance change at different part temperatures?
Calculate signed diametral clearance after hole and shaft undergo separate uniform temperature changes from one reference.
Open the calculatorRuns in your browser. No account needed.
How this tool works
Inputs, units and where to find them
| Input | Unit | Typical source |
|---|---|---|
| Hole diameter at reference temperature | mm | Actual or selected limit hole diameter at the reference temperature. |
| Shaft diameter at reference temperature | mm | Actual or selected limit shaft diameter at the same temperature. |
| Hole-material expansion coefficient | µm/(m·K) | Validated mean linear expansion coefficient for the hole material over its range. |
| Shaft-material expansion coefficient | µm/(m·K) | Validated mean coefficient for the shaft material over its range. |
| Common reference temperature | °C | Common temperature at which both entered diameters apply. |
| Hole operating temperature | °C | Uniform temperature of the hole-carrying part. |
| Shaft operating temperature | °C | Uniform operating shaft temperature. |
Method and formulas
- For each part: diameter at temperature = reference diameter × [1 + coefficient × 10⁻⁶ × temperature change].
- Signed diametral clearance = hole − shaft. Positive is gap; negative is geometric interference.
- Example: 50.02 mm hole with coefficient 23 and 50 mm shaft with coefficient 12, referenced at 20°C and operating at 80°C and 60°C, gives 50.0890276 and 50.024 mm. Clearance = 0.0650276 mm.
Limitations
- Uniform, unrestrained isotropic expansion with constant mean coefficients; gradients, coatings and constraint are excluded.
- Interference is geometric, not a contact-pressure or assembly-force result.
- Coefficients are user-supplied, and the examples do not select materials. Tolerance/temperature corner cases require separate evaluation.
- Default values are worked examples, not recommended settings or material properties.
Typical uses
- operating clearance
- differential expansion
- thermal interference
Who it is for
- Design engineers
- Maintenance engineers
What you get
- Operating diameters
- Reference and operating signed clearance
- Thermal clearance change
Interpreting the result
- Check minimum and maximum clearance across credible size and temperature conditions.
- Verify material data over the complete temperature range.
References
- Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 375–379. Topic reference; implementation and examples are original, and no source tables are reproduced.
WORKOS tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.