KEVOS® MAKEOS · Maintenance
Coolant Blend
What volumes make the required final coolant concentration?
Balance two compatible volume concentrations to prepare a specified final coolant volume.
Open the calculatorRuns in your browser. No account needed.
How this tool works
Inputs, units and where to find them
| Input | Unit | Typical source |
|---|---|---|
| Required final volume | L | Required final working volume with tank operating allowance. |
| Stronger-fluid concentration | % | Actual volume concentration of the stronger fluid; 100% denotes the same product concentrate. |
| Weaker-fluid concentration | % | Actual concentration of the weaker compatible fluid; 0% denotes intended make-up water. |
| Target concentration | % | Supplier-approved target for the operation. |
Method and formulas
- Stronger volume = final volume × (target − weaker concentration)/(stronger − weaker concentration). Weaker volume is the remainder.
- The stronger concentration must exceed the weaker, with the target between them. All percentages use the same volume basis.
- Example: 100 L at 5%, made from 100% concentrate and 0% water, requires 5 L concentrate and 95 L water under the additive-volume assumption.
Limitations
- Volumes are assumed additive. Mass-based concentrations require density-aware mass balance.
- Streams must be compatible forms of the same coolant system. No compatibility or mixing-order advice is inferred.
- Refractometer readings require the product-specific factor and contamination checks.
- Default values are worked examples, not recommended settings or material properties.
Typical uses
- coolant mixing
- dilution
- concentration balance
Who it is for
- Maintenance teams
- Machine shop supervisors
What you get
- Stronger-fluid volume
- Weaker-fluid volume
- Concentrate-equivalent balance
Interpreting the result
- Follow supplier mixing instructions, circulate and measure final concentration.
- Record actual quantities and check product range, water quality and coolant condition.
References
- Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 1182–1187. Topic reference; implementation and examples are original, and no source tables are reproduced.
- Blaser Swisslube: Measuring coolant concentration — https://blaser.com/measuring-the-coolant-concentration/
WORKOS tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.