Tank Wall Panel under Liquid Pressure (Force, Plate Stress, Deflection)

What liquid pressure and force act on this flat tank wall, and is a panel between stiffeners thick enough in stress and deflection?

Check of a flat-walled (rectangular) tank: pressure at the bottom, the resultant force on the wall and its centre of pressure (as the hydrostatic force tool), and a rectangular panel between stiffeners treated as simply supported under the bottom pressure (conservative), with its bending stress and centre deflection (as the rectangular plate tool), the thickness needed for the allowable stress, and checks against the allowable stress and deflection limit.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Liquid depthmDepth of liquid above the tank floor.
Liquid densitykg/m³Density of the liquid.
Wall widthmWidth of the wall.
Gas pressure above the liquidkPaGas or vapour pressure above the liquid (0 for an open tank).
Panel long side (between stiffeners)mmLonger side of the panel between stiffeners.
Panel short sidemmShorter side of the panel.
Plate thicknessmmPlate thickness (after corrosion allowance).
Elastic modulusGPaElastic modulus of the plate.
Allowable bending stressMPaAllowable bending stress in the plate (your design value).
Largest panel deflectionmmLargest deflection you accept at the panel centre.

Method and formulas

  1. Bottom pressure p = p_s + ρ g h; wall force = ρ g w h² ÷ 2 + p_s w h; centre of pressure from the floor (as the hydrostatic force tool).
  2. Simply supported rectangular panel under uniform pressure p: σ = 0.75 W ÷ [t² (L ÷ l + 1.61 l² ÷ L²)]; deflection = 0.1422 W ÷ [E t³ (L ÷ l³ + 2.21 ÷ L²)], W = p L l (as the rectangular plate tool).
  3. Thickness for the allowable: t = √{0.75 W ÷ [σ_allow (L ÷ l + 1.61 l² ÷ L²)]}.
  4. Example: 2 m of liquid gives 19.613 kPa at the floor; a 1000 × 600 mm panel of 7 mm plate runs at 80.187 MPa and deflects 3.5665 mm.

Limitations

  • The bottom pressure is applied to the whole panel (conservative for upper panels).
  • Stiffeners, corners and floor joints need their own design.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Size the plate of a rectangular water or chemical tank
  • Choose stiffener spacing for a tank wall
  • Check an existing tank for a heavier liquid

Who it is for

  • Structural engineers
  • Fabrication supervisors
  • Plant engineers

What you get

  • Bottom pressure, wall force and centre of pressure
  • Panel stress and deflection
  • Thickness needed and checks

Interpreting the result

  • Halving the short side of the panel cuts the stress roughly four times: closer stiffeners save plate.