KEVOS® MAKEOS · Hydraulics

Pipe or Hose Size for a Target Velocity

What inside diameter keeps this flow at the target velocity?

Minimum inside diameter of a pipe, tube or hose for a flow at a chosen mean velocity, and the velocity in a selected actual bore.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
FlowL/minMaximum flow in the line.
Target velocitym/sDesign velocity for the line type (typical hydraulic guidance: suction 0.6–1.2 m/s, return 1.5–3 m/s, pressure 3–6 m/s).
Actual inside diameter to check (0 = none)mmInside diameter of a proposed or existing pipe or hose.

Method and formulas

  1. d = √(4Q ÷ (π v)), Q in m³/s.
  2. Velocity in a bore = Q ÷ (π d² ÷ 4).
  3. Example: 80 L/min at 4 m/s needs at least 20.601 mm bore.

Limitations

  • Velocity guidance is not a pressure-drop check; long lines need the pipe friction tool too.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Size hydraulic suction, pressure and return lines
  • Size coolant and water pipes
  • Check an existing hose for velocity

Who it is for

  • Hydraulic and process engineers
  • Maintenance engineers
  • Design engineers

What you get

  • Minimum inside diameter
  • Velocity in the actual bore

Interpreting the result

  • Choose the next standard size at or above the minimum bore.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 3024–3027. Topic reference; no source tables or recommended settings are reproduced.

WORKOS tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.

Open the Pipe or Hose Size for a Target Velocity calculator